Configuration of parameters by front panel push GU601A Genset Controller buttons or by a PC via mini USB interface with license free software
Configurable fuel output energise to stop or energise to run
3 Configurable inputs
3 Configurable outputs
2 Analogue inputs configurable for different senders for Oil and Engine temperature
True RMS measuring
GU602A Engine Controller
Configuration of parameters by front panel push buttons or by PC via mini USB interface with license free software
Configurable fuel output energise to stop or energise to run
3 Configurable inputs
3 Configurable outputs
2 Analogue inputs configurable for different senders for Oil pressure and Engine temperature
Magnetic Pick-up
GU610A Genset Controller
Configuration of parameters by front panel push buttons or by a PC via mini USB interface
Configurable fuel output energise to stop or energise to run
3 Configurable inputs
3 Configurable outputs + 1 fixed output for GCR
True RMS measuring
Generator Phase voltage display
Generator Line voltage display
Generator Current display (three phases)
2 Analogue inputs configurable for different senders for Oil pressure and Engine temperature
GU6011A Genset Controller
Configuration of parameters by front panel push buttons or by PC via mini USB interface with license free software
Configurable fuel output energise to stop or energise to run
3 Configurable inputs
3 Configurable outputs + 2 fixed outputs for ATS control
2 Analogue inputs configurable for different senders for Oil pressure and Engine temperature
True RMS measuring
Mains phase voltage
Mains Line voltage
Generator current display (three phases)
Generator phase voltage display (single phase)
GU620A Genset Controller
128 x 64 graphic LCD
True RMS measuring
Configuration of parameters by front panel push buttons or communication software
RS485, RS232, or USB port for remote communication
Configurable fuel output energise to stop or energise to run
7 Configurable inputs
5 Configurable outputs, 1 used for GCR
2 Analogue inputs configurable for different senders for Oil pressure and Engine temperature
2 Aux configurable analogue inputs
Push Button for manual control of GCR
GU621A Genset Controller
128 x 64 graphic LCD display
True RMS measuring
Configuration of parameters by front panel push buttons or communications software
RS485, RS232, or USB port for remote communication
Configurable fuel output engergise to stop or energise run
7 Configurable inputs
5 Configurable outputs, 2 used for ATS control
2 Analogue inputs configurable for different senders for Oil pressure and Engine temperature
2 Aux. configurable analogue inputs
Push Buttons for manual control of GCR/MCR
GU630A Genset Controller
128 x 64 graphic LCD display
True RMS measuring
Configuration of parameters by front panel push buttons or communications software
RS485, RS232, or USB port for remote communication
Configurable fuel output engergise to stop or energise run
7 Configurable inputs
5 Configurable outputs, 2 used for ATS control
2 Analogue inputs configurable for different senders for Oil pressure and Engine temperature
2 Aux. configurable analogue inputs
Push Buttons for manual control of GCR/MCR
GU631A Genset Controller
128 x 64 graphic LCD display
True RMS measuring
Configuration of parameters by front panel push buttons or communications software
RS485, RS232, or USB port for remote communication
Configurable fuel output engergise to stop or energise run
7 Configurable inputs
5 Configurable outputs, 2 used for ATS control
2 Analogue inputs configurable for different senders for Oil pressure and Engine temperature
2 Aux. configurable analogue inputs
Real time clock and calendar
Event log
Exercise run schedule
Genset maintenance reminder
Push Buttons for manual control of GCR/MCR
GU640B Genset Controller
True RMS measuring
Configuration of parameters by front panel push buttons or communications software
RS485, RS232, or USB port for remote communications
Configurable fuel output energise to stop or energise to run
6 Configurable inputs
4 Configurable outputs, 1 used for GCR
2 Analogue inputs configurable for different senders for Oil pressure and Engine temperature
Push Button for manual control of GCR
Magnetic pick-up input
GU641B Genset Controller
True RMS measuring
Configuration of parameters by front panel push buttons or communications software
RS485, RS232, or USB port for remote communication
Configurable fuel output engergise to stop or energise run
6 Configurable inputs
4 Configurable outputs, 2 used for ATS control
2 Analogue inputs configurable for different senders for Oil pressure and Engine temperature
2 Aux. configurable analogue inputs
Push Buttons for manual control of GCR/MCR
Magnetic pick-up input
GU660A Genset Controller
True RMS measuring
Configuration of parameters by front panel push buttons or by licence free software, and can also select the working mode, start and stop the genset. There are LED indicators to show the working mode and running status. All the parameters are also displayed on the graphic LCD.
240*160 graphic LCD display
Real time clock and calendar
Event and Data log
Event log with running data record and time stamp
Genset exercise run schedule and maintenance reminder
Configurable sensor curve for oil pressure and engine temperature